How a plumbing business builds repeat work from servicing agreements: what to write, how to diary the visits, and how records and renewals are kept.
Key facts
- In the Sydney Water area, an owner who needs a testable backflow device must use an accredited backflow plumber to assess the hazard, install, test and register it, test it every year, and send the results within 2 days (Backflow prevention for businesses).
- A licensed plumber can install the device. An accredited backflow plumber tests and registers it. Prevention must comply with the Plumbing Code of Australia. Sydney Water audits a sample against AS/NZS 3500.1 and AS/NZS 2845. Its 20 mm and 25 mm meters already include a non-testable device for low-hazard connections.
- Other water utilities set their own rules. Read the page for the utility on that property.
- In NSW, a Notice of Work and a Certificate of Compliance apply to plumbing and drainage work, with exceptions. Replacing an existing hot water system is listed among minor works where a Notice of Work does not need to go to the regulator (Plumbing inspection documents).
- NSW Health policy PD2015_008, for hospitals under the Public Health Act 2010, requires a monthly temperature check of warm water from at least one outlet on each thermostatic mixing valve (policy PDF). That check is not a rule for a house.
What should a simple agreement cover?
A simple agreement names the sites, the assets you will service, how often you attend, and what a visit includes. It separates that visit from a repair or a part. It states the price for the included visits, how either side renews or ends it, and who can open the plant room.
Write each street address. List the assets you are taking on. Say what the visit includes, and what is a repair, a part or an after-hours call-out. Name who can open the plant room.
What you put on the public site is on websites for plumbers. Winning new local call-outs is covered in plumber marketing in Sydney and Melbourne.
How do you price the visits without inventing a figure?
Price the included visits as a set, and price everything outside that set as extra. There is no dollar figure here, because a house and a plant room with several devices are not the same job. Write the method in the agreement, and say it before the customer signs.
Split labour on the visit from parts, and say who approves a part before it is fitted. Name the suburbs and the hours. Travel outside them, and after-hours attendance, are extra.
A maintenance agreement is easier to renew when the customer can see how many visits they paid for and which call-outs sat outside it. At renewal, compare the time the visits took with the price you charged, and change the list or the price. A quote the visit uncovers is followed up separately, as set out on quote follow-up.
How do you build a service schedule the crew can run?
Build the service schedule from the assets, not from a hope that someone will remember. Each device gets its own line: site, what it is, where it sits, the last visit, and the next due date. One property can hold several lines. A single reminder for the whole site will miss the second device.
Hot water servicing is a visit you sell, not a law that every home must book each year. Use the interval the customer, the building owner or the valve maker has set, and do not call a household legally overdue when you cannot point to the rule.
Group due dates by suburb and leave a gap for the emergency that will land. A second person needs the same list. Reminder timing is in how a small business handles missed appointments.
Who does backflow testing in the Sydney Water area, and when?
Backflow testing of a testable device in the Sydney Water area is a yearly job for an accredited backflow plumber, and the results go to Sydney Water within 2 days. That is Sydney Water’s rule for its own area. Do not paste it onto every postcode.
A licensed plumber may install the device. The test and the registration sit with the accredited backflow plumber. Record type, size, location, last test and next due date, and roll the date forward the same day. Give the customer a copy of the report.
Outside the Sydney Water area, read that utility’s page before you quote a yearly test. Houses on a 20 mm or 25 mm Sydney Water meter are a different case: the meter already has a non-testable device. Do not sell those households a yearly test the page is not describing.
What thermostatic mixing valve work belongs on the agreement?
A thermostatic mixing valve on a hospital warm-water outlet is not the same job as a valve on a house. Hospitals covered by NSW Health policy PD2015_008 have a monthly temperature check from at least one outlet on each valve, plus a report when a valve is commissioned or serviced.
Read the policy before you quote a hospital. Do not copy the monthly check onto a house. For other buildings, take the interval from the valve maker and from the rules for that site. If you cannot point to a source, describe the visit as the service the customer asked for. Keep valve work on its own line, and have the licensed person sign the note.
Which compliance records do you keep with the job?
Compliance records show what was done, who did it, and who received a copy. In NSW they include the Certificate of Compliance, and a Notice of Work where the job needs one. The path differs by inspection area. Other states have their own forms.
Complete the Certificate of Compliance and give a copy to the person who arranged the work. Submit it to Building Commission NSW or the local regulator where an inspection is required. Replacing an existing hot water system is on the minor-works list. File the certificate and the service note on the property. That file does not replace a lodgement the regulator still wants. Choosing software for the dates is covered in plumbing business software in Australia.
How do reminders and renewals keep the work from going quiet?
Send the visit note early enough that the customer can pick a time and you can group the suburb. A message on the morning the test is due leaves no room to book. A second, shorter note close to the date catches people who did not answer.
Keep both factual: what is due, the address, and how to book or move the time. Do not add an offer. A message that promotes something follows different rules, set out in the missed-appointments guide linked above.
After the visit, move the next due date forward the same day and send the invoice from the same record. If the customer does not continue, leave the device on the property. The next occupier is easier to help if the history is still there.
Put a renewal reminder on the list a few weeks before the agreement ends, with a person named against it. The conversation is short: what you attended, what sat outside the agreement, and whether the asset list is still true. Then send the next agreement with the dates and the price method written in it.
Where do the dates and the reminders live?
The crew still does the work, and the licensed person still lodges the papers. The office side is a shared diary and a record the next person can open without ringing the one who went last time. That is the practical shape of plumbing maintenance contracts.
LYD Plumber backflow testing reminders keeps device details, the last test and the next due date on the property. A text and an email go out in your business name, with a booking link, before the due date. The same page uses that pattern for hot water servicing and for thermostatic mixing valve servicing where the client needs it. It does not lodge the test. The accredited tester does that.
Heating and air conditioning businesses that keep maintenance agreements have the same diary problem. The office side of that work is on HVAC business software.
Plans for Launch Your Dream are on the pricing page.
If the reminder path needs a workflow built around the way the office already runs, that is AI agent deployment from Sharktech Global. The same work on this site is AI agent deployment. If the computers and email also need looking after, that is managed IT support from Sharktech Global, and managed IT on this site. Sharktech Global serves NSW and regional NSW, Monday to Friday, 9am to 7pm, with after 7pm and Saturdays by appointment.
Book a free 30-minute meeting with our senior engineer in the online calendar.
General information for plumbing business owners, not legal, licensing or compliance advice. Check the water utility and the state plumbing regulator for the property before you quote a test or skip a form.
Common questions
- Does every house need a yearly backflow test?
- No. In the Sydney Water area the yearly test is for a testable device. Many low-hazard houses on a 20 mm or 25 mm meter have a non-testable device built into the meter. Check the water utility that supplies the property before you promise a test.
- Can any licensed plumber test and register a device with Sydney Water?
- Sydney Water says a licensed plumber can install the device, and an accredited backflow plumber tests it, registers it and confirms it is working. Some plumbers hold both qualifications.
- Is a monthly temperature check required on a house?
- Not under the NSW Health hospital policy. That monthly check of warm water applies to hospitals covered by the policy. A house follows the valve maker's instructions and the rules for that building.
- Does replacing an existing hot water unit always need a Notice of Work in NSW?
- NSW Government guidance lists replacing an existing hot water system among minor works where a Notice of Work does not need to be supplied to the regulator. You still complete a Certificate of Compliance and give a copy to the person who arranged the work. Inspection rules differ by area and by the job.
- Does the software lodge the test result with the water utility?
- No. The record and the reminder can sit in the system. The accredited tester still lodges the result the way that utility requires.
- Who built Launch Your Dream?
- Launch Your Dream is built and supported by Sharktech Global (opens in a new tab), an Australian managed IT and AI agent deployment company serving NSW and regional NSW.